Assay Method Information

Assay Name:  KHK Assay B
Description:  Compounds having an IC50 value less than 20 nM were examined in a second KHK assay, referred to as Assay B, using 10-fold less enzyme and measuring absorbance for 3 hours to obtain IC50 values below the 10 nM lower limit of Assay A. Compounds were prepared in DMSO as 4 μM stocks, diluted using an 11-point 2-fold dilution scheme on a Biomek FX spanning a concentration range of 97 μM to 100 nM, and incubated with reaction mixture prepared in a similar manner as in Assay A but containing 1 nM KHK-C. The reaction was initiated with addition of 0.2 mM ATP, and the absorbance was monitored for 3 hours at 340 nm. Reaction rates and IC50 values were calculated as described above.
Affinity data for this assay
 

If you find an error in this entry please send us an E-mail