Affinity DataKi: 51nMAssay Description:Manual Electrophysiology: On the day of experimentation, the 35 mm dish is placed on the stage of an inverted microscope equipped with a perfusion sy...More data for this Ligand-Target Pair
Affinity DataKi: 232nMAssay Description:Manual Electrophysiology: On the day of experimentation, the 35 mm dish is placed on the stage of an inverted microscope equipped with a perfusion sy...More data for this Ligand-Target Pair
Affinity DataKi: 240nMAssay Description:Manual Electrophysiology: On the day of experimentation, the 35 mm dish is placed on the stage of an inverted microscope equipped with a perfusion sy...More data for this Ligand-Target Pair
Affinity DataKi: 257nMAssay Description:Manual Electrophysiology: On the day of experimentation, the 35 mm dish is placed on the stage of an inverted microscope equipped with a perfusion sy...More data for this Ligand-Target Pair
Affinity DataKi: 317nMAssay Description:Manual Electrophysiology: On the day of experimentation, the 35 mm dish is placed on the stage of an inverted microscope equipped with a perfusion sy...More data for this Ligand-Target Pair
Affinity DataKi: 535nMAssay Description:Manual Electrophysiology: On the day of experimentation, the 35 mm dish is placed on the stage of an inverted microscope equipped with a perfusion sy...More data for this Ligand-Target Pair
Affinity DataIC50: 251nMAssay Description:Assay Buffer: The assay buffer was formulated by removing 120 mL from a 1 L bottle of fresh, sterile dH2O (Mediatech, Herndon, Va.) and adding 100 mL...More data for this Ligand-Target Pair
Affinity DataIC50: 291nMAssay Description:Assay Buffer: The assay buffer was formulated by removing 120 mL from a 1 L bottle of fresh, sterile dH2O (Mediatech, Herndon, Va.) and adding 100 mL...More data for this Ligand-Target Pair
Affinity DataIC50: 428nMAssay Description:Assay Buffer: The assay buffer was formulated by removing 120 mL from a 1 L bottle of fresh, sterile dH2O (Mediatech, Herndon, Va.) and adding 100 mL...More data for this Ligand-Target Pair
Affinity DataIC50: 502nMAssay Description:Assay Buffer: The assay buffer was formulated by removing 120 mL from a 1 L bottle of fresh, sterile dH2O (Mediatech, Herndon, Va.) and adding 100 mL...More data for this Ligand-Target Pair
Affinity DataIC50: 987nMAssay Description:Assay Buffer: The assay buffer was formulated by removing 120 mL from a 1 L bottle of fresh, sterile dH2O (Mediatech, Herndon, Va.) and adding 100 mL...More data for this Ligand-Target Pair
Affinity DataIC50: 1.52E+3nMAssay Description:Assay Buffer: The assay buffer was formulated by removing 120 mL from a 1 L bottle of fresh, sterile dH2O (Mediatech, Herndon, Va.) and adding 100 mL...More data for this Ligand-Target Pair
Affinity DataIC50: 1.54E+3nMAssay Description:Assay Buffer: The assay buffer was formulated by removing 120 mL from a 1 L bottle of fresh, sterile dH2O (Mediatech, Herndon, Va.) and adding 100 mL...More data for this Ligand-Target Pair
Affinity DataIC50: 2.20E+3nMAssay Description:Assay Buffer: The assay buffer was formulated by removing 120 mL from a 1 L bottle of fresh, sterile dH2O (Mediatech, Herndon, Va.) and adding 100 mL...More data for this Ligand-Target Pair
Affinity DataIC50: 2.35E+3nMAssay Description:Assay Buffer: The assay buffer was formulated by removing 120 mL from a 1 L bottle of fresh, sterile dH2O (Mediatech, Herndon, Va.) and adding 100 mL...More data for this Ligand-Target Pair
Affinity DataIC50: 2.84E+3nMAssay Description:Assay Buffer: The assay buffer was formulated by removing 120 mL from a 1 L bottle of fresh, sterile dH2O (Mediatech, Herndon, Va.) and adding 100 mL...More data for this Ligand-Target Pair
Affinity DataIC50: >2.00E+4nMAssay Description:Assay Buffer: The assay buffer was formulated by removing 120 mL from a 1 L bottle of fresh, sterile dH2O (Mediatech, Herndon, Va.) and adding 100 mL...More data for this Ligand-Target Pair