| Assay Method Information | |
| | Enzyme Activity Inhibition Assay |
| Description: | HDAC enzyme activity was measured using a HDAC Fluorimetric Drug Discovery Kit (BML-AK511, 516, Enzo Life Science). For the HDAC1 enzyme activity test, human recombinant HDAC1 (BML-SE456) was used as an enzyme source, and Fluor de Lys-SIRT1 (BNL-KI177) was used as a substrate. A 5-fold dilution of the compound was seeded into a 96-well plate, and then 0.3 μg of the enzyme and 10 μM of the substrate were added to each well of the plate and allowed to react at 30 for 60 minutes. Then, Fluor de LysDeveloper II (BML-KI176) was added thereto and allowed to react for 30 minutes, after which the fluorescence value (Ex 360, Em 460) was measured using a multi-plate reader (Flexstation 3, Molecular Device). The HDAC6 enzyme was tested using human recombinant HDAC6 (382180) (Calbiochem) according to the same protocol as the HDAC1 enzyme activity test method. |
| Affinity data for this assay | |
|---|---|
| If you find an error in this entry please send us an E-mail | |