Assay Method Information

Assay Name:  ThermoFluor Assay
Description:  1,8-ANS (Invitrogen) was used as a fluorescent dye. Protein and compound solutions are dispensed into black 384-well polypropylene PCR microplates (Abgene) and overlayed with silicone oil (1 μL, Fluka, type DC 200) to prevent evaporation.Bar-coded assay plates are robotically loaded onto a thermostatically controlled PCR-type thermal block and then heated at a typical ramp-rate of 1° C./min for all experiments. Fluorescence was measured by continuous illumination with UV light (Hamamatsu LC6) supplied via fiber optic and filtered through a band-pass filter (380-400 nm; >6 OD cutoff). Fluorescence emission of the entire 384-well plate was detected by measuring light intensity using a CCD camera (Sensys, Roper Scientific) filtered to detect 500±25 nm, resulting in simultaneous and independent readings of all 384 wells. Images were collected at each temperature, and the sum of the pixel intensity in a given area of the assay plate was recorded versus temperature. Reference wells contained RORγt without compounds, and the assay conditions were as follows: 0.065 mg/mL RORγt 60 μM 1,8-ANS 100 mM Hepes, pH 7.0 10 mM NaCl 2.5 mM GSH 0.002% Tween-20
Affinity data for this assay
 

If you find an error in this entry please send us an E-mail