Assay Method Information

Assay Name:  Electrophysiological Assay
Description:  Clamped the cell at −80 mV and then depolarized to 10 mV with a square wave lasting 10 ms to get the Nav1.8 current (see FIG. 1 attached). This procedure was repeated every 5 seconds. The maximum current triggered by the square wave was detected, and when it stabilized, the test compounds were perfused, and when the reaction stabilized, the strength of the block was calculated.
Affinity data for this assay
 